Hits:552

Smart Micro Ultrasonic water meter

Name Micro Ultrasonic water meter
Brand Zysmart Water Meter
Model ZYLXSG-UL-3
Inventory 1000

一、Product Summary
Ultrasonic water meter is used to accurately measure the flow rate. The product has the characteristics of beautiful appearance, convenient installation, accurate measurement, stable operation, strong anti-pollution and anti-corrosion capability, long service life, small pressure loss, economy and practicality, etc. It is suitable for flow metering and charging of domestic water, central air conditioning system water, etc.
Implementation standard: GB/T 778 Measurement of water flow in closed full pipeline Drinking cold water meter and hot water meter JJG 162-2009 Cold water meter
二、Working Principle
Ultrasonic water meter adopts the principle of ultrasonic wave. It is a kind of water meter that further calculates the flow rate of water by analyzing and processing the time difference caused by the change of speed when ultrasonic sound beam propagates downstream and countercurrent in water.




三、Function List

 

Serial Number

Functions

Comments

1

Metering function

Accumulated flow of real-time Hall counter

2

Water metering data history storage local

1. For the latest 90 days, the measurement data is stored every hour

2. The latest 180 days, the measurement data is stored every day

3. Monthly storage of measurement data in the latest year

3

Power supply

1. Battery powered

2. External power supply

4

Main battery capacity level indication

The suffix of that current battery capacity level is report to the server in each metering data message uplink report

5

LED indication

Communication events; Screen Cutting Event

6

Manual triggering (triggering varies according to different models)

Button triggers an escalation event

Magnet triggers report event

Trigger 1 second switch screen

Trigger 2 seconds to report data

Trigger more than 9 seconds to restart the device

7

Wireless technology

Lorawan/NB

8

Display Range

0~99999.999

9

Periodic reporting

1 The default period is 24 hours

Latest cumulative measurement data

Water meter status: valve status/power supply

Battery Capacity Level

Downlink Signal Strength Indication

10

Timed reporting

1 Fixed time (for example, 23:00, also configurable) triggers metering data reports every day, and the message payload is the same as the periodic report

Latest cumulative measurement data

Water meter status: valve status/power supply

Battery Capacity Level

5LoRaWAN Downlink Signal Strength Indication RSSI/SNR

11

Alarm Message Uplink Report

Battery Capacity Low Level Alarm

Backup Battery Switch Alarm

Valve fault alarm

12

Screen digital display

1 Display content: current reading, electric quantity, balance and valve status (default valve opening status of non-valve controlled water meter)

2 Display mode: normally bright (low power consumption screen)

13

Mode of transport

In the transportation mode, log is closed, communication is closed, pulse is not metered, and the operation with minimum power consumption is maintained

14

Antenna (NB/Lorawan)

Built-in antenna (spring/soft antenna)

External antenna (chuck antenna)

15

Infrared Configuration (Optional, Default None)

Infrared Setting/Read Table Parameters

Infrared Update Program

16

Communication mode

Supported Band

 

M66 (GPRS Communications)

850/900/1800/1900MHz

 

BC26 (NB Communications)

B1/B2/B3/B4/B5/B8/B12/B13/B17/B18/B19/B20/B25/B26/B28/B66

 

BC35G (NB Communications)

B1 @ H-FDD: 2100 MHz

B3 @ H-FDD: 1800 MHz

B8 @ H-FDD: 900 MHz

B5 @ H-FDD: 850 MHz

B20 @ H-FDD: 800 MHz

B28 @ H-FDD: 700 MHz

 

BG96 (NB Communications)

Cat M1/Cat NB1:

LTE FDD: B1/B2/B3/B4/B5/B8/B12/B13/B18/

B19/B20/B26/B28

LTE TDD: B39 (For Cat M1 Only)

EGPRS:

850/900/1800/1900MHz

BG96-M

Cat M1:

LTE FDD: B1/B2/B3/B4/B5/B8/B12/B13/B18/

B19/B20/B26/B28

LTE TDD: B39

 

BC66 (NB Communications)

B1/B2/B3/B4/B5/B8/B12/B13/B17/B18/B19/B20/

B25/B26*/B28/B66

 

Lorawan Newsletter

CLASSA, CLASSB and CLASSC modes are supported, and the supported frequency bands are shown in the attachment

 

Battery life

Ten years

 


technical parameter
R 250
OT 5-55℃
class B