What's wrong with the gas meter saying the valve



 Currently, with the popularization of natural gas, many households are using clean natural gas energy, and smart gas meters, which are the most important in the field of civil natural gas metering, have also entered the homes of gas users.

For ordinary users, the most obvious difference between smart gas meters and traditional diaphragm gas meters is

that valves and related control modules are added inside the smart gas meters, thereby enabling prepayment of "pay first, use gas later" Function.

And not only this, the smart gas meter can control the switching of the valve according to different situations, so that while ensuring metering, it can provide all-round protection for the meter and safe gas use. For example, the leakage alarm and valve closing function of the smart gas meter can be used through The data line is connected to an external gas leak alarm. After the alarm detects a gas leak, it will send a leak signal to the meter. At this time, the meter will automatically cut off the valve in the meter, thereby further ensuring the safety of gas consumption.   


 How to open the valve of the smart gas meter when it is closed?

 

1. If the balance is insufficient, the valve will be closed. The remaining gas volume or amount in the meter is 0. Please go to the gas company to recharge in time or recharge through other channels;

2. When the power is turned off and the valve is closed, the battery in the meter is insufficient. The battery should be replaced in time, usually 4 AA dry batteries. It is recommended to replace the battery with better quality;

3. Close the valve with strong magnetic protection. Please check whether there are strong magnetic field objects around the gas meter, such as induction cookers, rice cookers, etc., and move them to a farther location;

4. Leakage alarm alarms and the valve closes (for smart gas meters with gas leakage alarm linkage). The gas leakage alarm detects gas leakage and closes the valve in the meter. In this case, it is recommended to contact the gas company to detect whether there is any leakage, and process it timely.

5、The overcurrent protection valve closes and the gas consumption flow is too large. This situation will occur after exceeding the rated maximum flow rate of the meter and continuing for a period of time. Please check whether there is an excessive peak gas consumption and replace the gas meter with a larger flow specification;

6. Small flow leakage will close the valve. Not only the gas meter will close the valve if the flow rate is too small, but it will also close the valve if the flow rate is too small. In this case, if the flow rate of the meter is lower than the set minimum value within a continuous period of time, it will be judged as a meter. If a leak occurs and the valve is closed, it is recommended to contact the gas company for handling;

 

7. If the gas is not used for a long time, the valve will be closed. If the gas is not used for a long time and exceeds the set number of days, the meter will automatically close the valve for protection;

 

8. The counting part of the meter fails. This situation is caused by the out-of-sync between the mechanical and intelligent parts of the meter. You need to contact the gas company for handling.