一、Product Summary
Dear users, thank you for using our electromagnetic flowmeter. Please read this instruction manual carefully before using it, so that you can easily use our products.
二、Working Principle
The working principle of the rotor electromagnetic flowmeter is that the water flow tangentially impacts the impeller from the water inlet of the watch case to rotate it, and then continuously records the number of revolutions of the impeller through the gear reduction mechanism, thus recording the cumulative flow through the water meter.
三、Function List
Serial Number |
Functions |
Comments |
1 |
Metering function |
Accumulated flow of real-time Hall counter |
2 |
Water metering data history storage local |
1. For the latest 90 days, the measurement data is stored every hour 2. The latest 180 days, the measurement data is stored every day 3. Monthly storage of measurement data in the latest year |
3 |
Power supply |
1. Battery powered 2. External power supply |
4 |
Main battery capacity level indication |
The suffix of that current battery capacity level is report to the server in each metering data message uplink report |
5 |
LED indication |
Communication events; Screen Cutting Event |
6 |
Manual triggering (triggering varies according to different models) |
Button triggers an escalation event Magnet triggers report event Trigger 1 second switch screen Trigger 2 seconds to report data Trigger more than 9 seconds to restart the device |
7 |
Wireless technology |
Lorawan/NB/GPRS |
8 |
External Interface |
RS485/Mbus |
9 |
Periodic reporting |
1 The default period is 24 hours Latest cumulative measurement data Water meter status: valve status/power supply Battery Capacity Level Downlink Signal Strength Indication |
10 |
Timed reporting |
1 Fixed time (for example, 23:00, also configurable) triggers metering data reports every day, and the message payload is the same as the periodic report Latest cumulative measurement data Water meter status: valve status/power supply Battery Capacity Level 5LoRaWAN Downlink Signal Strength Indication RSSI/SNR |
11 |
Alarm Message Uplink Report |
Battery Capacity Low Level Alarm Backup Battery Switch Alarm Valve fault alarm |
12 |
Screen digital display |
1 Display Content: Current Reading, Electricity Quantity, Balance, Valve Status (Default on, Because Cold Water Meter Has No Valve) 2 Display mode: normally bright (low power consumption screen) |
13 |
Mode of transport |
In the transportation mode, log is closed, communication is closed, pulse is not metered, and the operation with minimum power consumption is maintained |
14 |
Antenna (Nb/Lorawan/GPRS) |
Built-in antenna (spring/soft antenna) External antenna (chuck antenna) |
15 |
Infrared Configuration (Optional, Default None) |
Infrared Setting/Read Table Parameters Infrared Update Program |
16 |
Communication mode |
Supported Band |
|
M66 (GPRS Communications) |
850/900/1800/1900MHz |
|
BC26 (NB Communications) |
B1/B2/B3/B4/B5/B8/B12/B13/B17/B18/B19/B20/B25/B26/B28/B66 |
|
BC35G (NB Communications) |
B1 @ H-FDD: 2100 MHz B3 @ H-FDD: 1800 MHz B8 @ H-FDD: 900 MHz B5 @ H-FDD: 850 MHz B20 @ H-FDD: 800 MHz B28 @ H-FDD: 700 MHz |
|
BG96 (NB/GPRS/CATM Communications) |
Cat M1/Cat NB1: LTE FDD: B1/B2/B3/B4/B5/B8/B12/B13/B18/ B19/B20/B26/B28 LTE TDD: B39 (For Cat M1 Only) EGPRS: 850/900/1800/1900MHz BG96-M Cat M1: LTE FDD: B1/B2/B3/B4/B5/B8/B12/B13/B18/ B19/B20/B26/B28 LTE TDD: B39 |
|
BC66 (NB Communications) |
B1/B2/B3/B4/B5/B8/B12/B13/B17/B18/B19/B20/ B25/B26*/B28/B66 |
|
Lorawan Newsletter |
CLASSA, CLASSB and CLASSC modes are supported, and the supported frequency bands are shown in the attachment |
|
RS485 communication |
Four lines: red +, black-, yellow A, blue B |
四、Performance characteristics
Electromagnetic flowmeter has the characteristics of small size, simple structure, light weight, low cost and long working life.
The measurement accuracy is not affected by the type of medium to be measured and its physical parameters such as temperature, viscosity and density.
五、Technical Parameters
Nominal size |
DN50 ~ DN300 |
Instrument Accuracy |
R1.5 |
Flow rate range |
-12 … + 12m/s |
Working pressure |
1.6 mpa |
Electrical conductivity |
> = 300 µ S/cm |
Level of protection |
IP65 |
Ambient Temperature |
-20 ℃ ~ 60 ℃ |
Frequency |
48-60 Hz |
Pulse output |
3000cp/s pulse width, automatically adjusted according to customer settings |
Communication mode |
Lorawan/NB/GPRS/RS485 |
Voltage |
220V (working range: 100-230V) DC voltage: 22V |
Output Current |
4-20MA |
Lining material |
Rubber lining |
六、Product structure and size
caliber |
H(mm) |
L(mm) |
D(mm) |
DN100 |
420 |
240 |
210 |
DN150 |
500 |
290 |
280 |
DN200 |
520 |
340 |
330 |
DN250 |
560 |
410 |
400 |
DN300 |
580 |
510 |
510 |
Nominal diameter | DN50~DN300 |
Instrument accuracy | R1.5 |
Flow rate range | -12… +12m/s |
working pressure | 1.6mpa |
Electrical conductivity | >=300 µS/cm |
Protection level | >=300 µS/cm |
ambient temperature | -20 ℃ ~ 60 ℃ |
frequency | 48 -60 Hz |
Pulse output | 3000cp / s pulse width, automatically adjusted according to customer's setting |
Communication mode | Lorawan / NB / GPRS / RS485 |
Voltage | 220V (Scope of work:100-230V)DC voltage:22V |
Output current | 4-20MA |
Lining material | Rubber lining |