Hits:3610

Large caliber water meter

name Large caliber water meter
brand Zysmart Water Meter
model ZYLXL
inventory 1000

一、Product Summary

Dear users, thank you for using our large-caliber water meter. Please read this instruction manual carefully before using it, so that you can easily use our products.

Large-diameter water meter is a measuring instrument used to measure the total volume of water flowing through tap water pipes, which is suitable for small-scale industrial water and residential water. Dry structure, vacuum sealing of counting mechanism, no influence of water quality on the wheel of dial, and permanent clear reading. The word wheel display counter value has large measuring range and high precision. The metering and other performance requirements meet GB/T 778.1 ~ 3-2007 Class B standard, and the electronic device meets the "Electronic Remote Transmission Water Meter" (CJ/T 224-2006) standard.

二、Working Principle

Compared with the traditional pulse water meter, the large-diameter water meter can reduce the metering error to almost zero, which is an ideal metering zero-error water meter in the automatic meter reading system. Moreover, it adopts a low power consumption design, so it is not necessary to supply power normally, and it is only necessary to power up the water meter when it reads.

三、Function List

Serial Number

Functions

Comments

1

Metering function

Accumulated flow of real-time Hall counter

2

Water metering data history storage local

1. For the latest 90 days, the measurement data is stored every hour

2. The latest 180 days, the measurement data is stored every day

3. Monthly storage of measurement data in the latest year

3

Power supply

1. Battery powered

2. External power supply

4

Main battery capacity level indication

The suffix of that current battery capacity level is report to the server in each metering data message uplink report

5

LED indication

Communication events; Screen Cutting Event

6

Manual triggering (triggering varies according to different models)

Button triggers an escalation event

Magnet triggers report event

Trigger 1 second switch screen

Trigger 2 seconds to report data

Trigger more than 9 seconds to restart the device

7

Wireless technology

Lorawan/NB/GPRS

8

External Interface

RS485/Mbus

9

Periodic reporting

1 The default period is 24 hours

Latest cumulative measurement data

Water meter status: valve status/power supply

Battery Capacity Level

Downlink Signal Strength Indication

10

Timed reporting

1 Fixed time (for example, 23:00, also configurable) triggers metering data reports every day, and the message payload is the same as the periodic report

Latest cumulative measurement data

Water meter status: valve status/power supply

Battery Capacity Level

5LoRaWAN Downlink Signal Strength Indication RSSI/SNR

11

Alarm Message Uplink Report

Battery Capacity Low Level Alarm

Backup Battery Switch Alarm

Valve fault alarm

12

Screen digital display

1 Display content: current reading, electric quantity, balance and valve status (default valve opening status of non-valve controlled water meter)

2 Display mode: normally bright (low power consumption screen)

13

Mode of transport

In the transportation mode, log is closed, communication is closed, pulse is not metered, and the operation with minimum power consumption is maintained

14

Antenna (Nb/Lorawan/GPRS)

Built-in antenna (spring/soft antenna)

External antenna (chuck antenna)

15

Infrared Configuration (Optional, Default None)

Infrared Setting/Read Table Parameters

Infrared Update Program

16

Communication mode

Supported Band

 

M66 (GPRS Communications)

850/900/1800/1900MHz

 

BC26 (NB Communications)

B1/B2/B3/B4/B5/B8/B12/B13/B17/B18/B19/B20/B25/B26/B28/B66

 

BC35G (NB Communications)

B1 @ H-FDD: 2100 MHz

B3 @ H-FDD: 1800 MHz

B8 @ H-FDD: 900 MHz

B5 @ H-FDD: 850 MHz

B20 @ H-FDD: 800 MHz

B28 @ H-FDD: 700 MHz

 

BG96 (NB/GPRS/CATM Communications)

Cat M1/Cat NB1:

LTE FDD: B1/B2/B3/B4/B5/B8/B12/B13/B18/

B19/B20/B26/B28

LTE TDD: B39 (For Cat M1 Only)

EGPRS:

850/900/1800/1900MHz

BG96-M

Cat M1:

LTE FDD: B1/B2/B3/B4/B5/B8/B12/B13/B18/

B19/B20/B26/B28

LTE TDD: B39

 

BC66 (NB Communications)

B1/B2/B3/B4/B5/B8/B12/B13/B17/B18/B19/B20/

B25/B26*/B28/B66

 

Lorawan Newsletter

CLASSA, CLASSB and CLASSC modes are supported, and the supported frequency bands are shown in the attachment

 

RS485 communication

Four lines: red +, black-, yellow A, blue B

 

四、Performance characteristics

1. Mechanical measurement and other performance requirements meet GB/T778.1 ~ 3-2007; The electronic device meets the standard of Electronic Remote Transmission Water Meter (CJ/T224-2012);

2. Compared with the traditional pulse water meter, it can reduce the reading error to almost zero due to the direct reading of word wheel data.

3. Low power consumption design is adopted, and power supply is required only when reading.

4. Advanced data coding and verification methods are adopted, with high communication reliability.

5. Meet the design requirements of EMC, ESD, EMI and other electronic products in terms of electromagnetic compatibility, reaching the industry leading level.

6. Combining with the upper computer system, a remote automatic meter reading management system is established to truly realize meter reading automation.

 

五、Technical Parameters

 

Model

Overload flow

Q4

Common flow

Q3

Boundary flow

Q2

Minimum flow

Q1

Minimum reading

Maximum reading

M3/h

M3

ZYLXL-50Z/R

31.25

25

3.15

0.5

0.01

999999

ZYLXL-65Z/R

50

40

5.04

0.8

0.01

999999

ZYLXL-80Z/R

78.75

63

7.94

1.26

0.01

999999

ZYLXL-100Z/R

125

100

12.6

2

0.01

999999

ZYLXL-150Z/R

312.5

250

31.5

5

0.1

999999

ZYLXL-200Z/R

500

400

50.4

8

0.1

999999

ZYLXL-250Z/R

787.5

630

79.4

12.6

0.1

999999

ZYLXL-300Z/R

1250

1000

126

20

0.1

999999

 

六、Product structure and size

The outline of the water meter is shown below,



  

See the following table for water meter dimensions.

Model

Caliber

Long L

High H

High G

Connecting flange

Weight

Mm

Mm

Flange outer diameter D

Center of bolt hole is round and straight

Diameter D1

Number of connecting bolts (only)

Kg

ZYLXL-50Z/R

50

200

255.8

400

165

125

4M16Í

12

ZYLX L-80Z/R

80

225

275.8

400

200

160

8M16Í

16

ZYLX L-100Z/R

100

250

285.8

400

220

180

8M16Í

18

ZYLXL-150Z/R

150

300

345.3

500

285

240

8M16Í

42

ZYLXL-200Z/R

200

350

372.5

500

340

295

8M16Í

64

ZYLXL-250Z/R

250

450

492.8

730

395

350

12M20Í

94

ZYLXL-300Z/R

300

500

515.8

730

445

400

12M20Í

114

technical parameter
The largest reading 999999
The minimum reading 0.01